How to share USB dongle over LAN or Internet Software developers want to secure their products from copying; to that end they introduce dongles. Users want just the opposite – to make using software as simple and convenient as possible, no extra security layers or tricks, please. Order the dongle backup as soon as possible - it's cheaper to make the software copy of the working key than replace dongle when it is lost! Click here to send us an e-mail. An additional solution is to insure your dongle but that would not cover you from loss-of-access to your protected software. Dongle emulator.
Bagaimana cara kerja Software Protection Dongle? Fungsi utama Software Protection Dongle ialah meng-enkripsi, nah dalam melindungi software / Aplikasi maka Software Protection Dongle akan mengubah Kode Panggil suatu Software (Encrypt) dan satu-satunya yang bisa membaca kode enkripsi itu hanya Dongle, sehingga tanpa adanya dongle maka Software yang sudah di enkripsi tersebut tidak akan bisa dijalankan. Itulah mengapa Software Protection Dongle jauh lebih efektif mengatasi permasalahan soal pembajakan dan pemakaian aplikasi oleh user yang tidak memiliki hak akses daripada sistem serial number yang mudah di tembus dengan membuat program validasi (Patch). Software Protection Dongle bisa melindungi hampir semua aplikasi baik aplikasi stand alone, Aplikasi berbasis Server - Client maupun Aplikasi berbasis Web. Postingan Sebelumnya. Apa itu Dongle?
Pertanyaan ini sering sekali terlontar akhir2 ini, biarpun banyak website yang mendeskripsikan definisi dongle tapi informasi yang kurang lengkap malah membuat kita jadi makin bingung. Dongle adalah: Sebuah Perangkat Keras atau Hardware dengan bentuk USB interface yang berfungsi untuk meng-enkrip (Membuat kode enkripsi). Kemajuan technology Dongle berkembang sangat cepat, Dongle ditemukan pertama kali pada awal 1980-an, Dongle ditujukan sebagai Copy / License Protection, fungsinya waktu itu khusus untuk melindungi hak cipta atau lisensi pada software yang disebut Software Protection Dongle. Software Protection Dongle: Alat berupa USB interface yang berfungsi melindungi Software dari pembajakan maupun dari user yang tidak memiliki hak untuk mengakses suatu aplikasi. Bentuk Software Protection Dongle: Sejak Diciptakan pada akhir 1980 an bentuk Dongle terus berubah sesuai dengan jenis port yang banyak digunakan.
Kini Software Protection Dongle hadir dalam bentuk USB Interface, sekilas ukuran maupun tampilan Software Protection Dongle ini mirip-mirip dengan Flash Disk, tapi fungsinya jelas sangat berbeda. Saat ini terdapat 2 jenis Software Protection Dongle yaitu Hardware Platform EEPROM dan Smartchip Microprocessor base. Dongle dengan platform hardware EEPROM bisa dibilang teknologi lama, salah satu kekurangan dongle jenis ini ialah hardware masih bisa di duplikasi, tapi Produk dongle EEPROM sekarang sudah banyak dilengkapi sistem password yang lebih rumit untuk mencegah penduplikasian hardware, bahkan Salah satu Dongle berplatform EEPROM yang di keluarkan oleh sudah menerapkan sistem Seed Code Password, produk ini dinamakan Secure Dongle X. Jenis kedua yaitu Software Protection Dongle yang berbasis Smartchip Microprocessor dikembangkan untuk menutupi kekurangan Dongle jenis pertama, dengan menggunakan Microprocessor maka dapat dipastikan Hardware tidak bisa di duplikasi. Kelebihan lainnya teknologi smartchip ini juga bisa menjalankan instruksi Algoritma yang mana hal ini sangat besar manfaatnya bagi para Programmer atau Pengembang Software.
Itulah sebabnya para Software Developer atau pengembang Software beralih menggunakan Dongle dan meninggalkan sistem perlindungan software yang lama seperti serial number, activation code dll. Posting Selanjutnya.
Below is a flowchart to help identify which category your issue applies to. Troubleshooting sections for each category are below the flowchart.
Section 1 - Troubleshooting HASP errors You may receive a HASP related error during the Intella installation process. Below you'll find a list of the errors which have been reported to us, together with the solutions for these errors. Error code 7 (H0007) 'HASP key not found (H0007)' This error code might be caused by other HASP dongle protected programs. Please close down all HASP related programs (i.e.
EnCase, Smart Mount) and reinstall Intella. Error code 27 (H0027) 'Terminal services detected, cannot run without a dongle (H0027)' NOTE: See This error code may be triggered because you are trying to use Intella via a remote desktop connection. Intella will only run via a RDP or terminal session with the dongle in place. Error code 33 (H0033) 'Unable to access HASP SRM Run-Time Environment (H0033)' HASP Error 33 means that the dongle driver has been blocked or deleted.
This is usually because of security software such as antivirus software/firewall getting in the way or removing vital files. Intella will need to be reinstalled to fix the issue. You will need to turn off your security software and then reinstall Intella as administrator. Also make sure that the Intella files and the Hasp files are added to the white list of any security software which you are running on the system. Error code 37 (H0037) This error code can be caused by other HASP dongle protected programs. Please close down all HASP related programs (i.e.
EnCase, Smart Mount) and reinstall Intella. If this problem persists, open a Command Prompt (as administrator) and run: bin haspdinst.exe -kp -i and restart Intella. If problem persists, open a Command Prompt (as administrator) and start the license manager by running: net start hasplms Tip: To open a Command Prompt as an administrator, select Start Accessories - Right click on Command Prompt and select 'Run as administrator'. Error code 41 (H0041) 'Your Intella (trial) license has expired (H0041)' This code is triggered if your trial license is expired. You can only keep on using Intella with a USB dongle.
Error code 51 (H0051) 'Virtual machine detected, cannot run without a dongle (H0051)' In order to protect our intellectual property, the evaluation version of Intella WILL NOT run in a virtual machine (VM) environment. A “stand-alone” physical machine is required.
This is only true for the evaluation version and Intella P.I. Intella will run in a VM environment using a dongle.
Reconnect the USB dongle to your computer Solution 2. Install the Intella evaluation version outside a virtual machine Error codes (E1009) or (E0004) ' Win32 Envelope - Data Loader Initialization Error' or 'Cannot find HASP SRM Run-Time Environment DLL' This error is shown when you are running an older driver for the dongle management system. It can happen when installing an older version of Intella or Connect. Try updating the driver to resolve the issue. 1) Stop Connect and any Intella instances that you may be running on this machine. 2) Visit 3) In the 'Featured Downloads' section at the top, choose 'Sentinel HASP/LDK - Windows GUI Run-time Installer' version 7.65 (this was the latest version at this writing).
4) Run this installer on your Connect machine. 5) Start Connect. Section 2 - Troubleshooting dongle not being detected issues You may experience an issue where the dongle has been working fine, but then is suddenly not detected by Intella. You may get the HASP key not found (H0007) error when this happens. There are several causes for this issue.
The first steps to take are to check whether there is a hardware issue: 1) Make sure that the dongle is plugged into the computer properly. If you are using a USB hub, try plugging the dongle directly into the computer. 2) Disconnect the dongle, pause a few seconds, then reconnect it again. If the LED lights up, the application should be able to access the dongle. You may need to wait a few seconds for the dongle to be completely installed by the operating system. 3) Check if the USB port is functioning correctly. Disconnect all other USB devices from their respective ports and connect the HASP dongle to a different USB port.
You can also try using a different USB device in the port which the dongle was not accessible to verify that the port is actually working. If you are still experience problems with the dongle not being detected and it is not a hardware issue, it may be a software issue. One of the most common causes for a dongle not being detected is when the dongle driver has been blocked or deleted.
As mention above with Error Code 33 (H0033), this is usually because of security software such as antivirus software/firewall getting in the way or removing vital files. You may be able to uninstall and reinstall the HASP driver to solve your problem by following these steps: 1) Temporarily disable any security software you have running on the system. 2) Open a Command Prompt (as administrator) 3) Change the bin directory of the Intella installation directory for Intella (e.g.